The economic drive solution for applications up to 7.5 kW. The X200 frequency inverters are suitable for pump and fan applications as well as for common tasks in machine construction. With the integrated EMC filter the inverter fullfills EN61800-3 standard and is complying with standards like CE, UL, cUL, c-Tick and RoHS.

product_inv-x200_center

  • 0.2 ~ 7.5 kW
  • Integrated EMC Filter
  • Automatic Energy saving function
  • RS485 Interface with Modbus RTU on board
  • Network Options: Profibus, CanOpen
  • RoHS Compliance
  • Side-by-Side installation
  • Global standards CE, UL, c-UL und c-Tick
anker
X200 1- / 3-phase 200 V class
Model number 002 SFEF 004 SFEF 005 SFEF 007 SFEF 011 SFEF 015 SFEF 022 SFEF
Applicable motor (kW) 0.2 0.4 0.55 0.7 1.1 1.5 2.2
Rated output current (A) 1.4 2.6 3.0 4.0 5.0 7.1 10.0
Rated input voltage 1 ~ 200 … 240 V, +10 %, -15 %, 50/60 Hz ±5 %
Rated output voltage 3 ~ 200 … 240 V (corresponding to input voltage)
Integrated EMC filter EN61800-3 category C1 filter
Output frequency range 0.5 … 400 Hz
Frequency accuracy (at 25 °C ±10 °C) Analogue setting: ±0.4 %, digital setting: ±0.01 %
Frequency setting resolution Analogue setting: Maximum frequency/1000, digital setting: 0.1 Hz
V/f characteristics V/f control, V/f variable (constant torque, reduced torque)
Overload capacity 150 % for 60 s
Acceleration/deceleration time 0.01 - 3000 s (linear, sigmoid), two stage accel./decel.
Starting torque 100 % at 6 Hz
Input Intelligent input terminal 10 kOhm input impedance, sink / source logic selectable
Functions FW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR, NO(Not selected)
Output Intelligent output terminal 27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)
Functions RUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load)
Analogue output terminal 0 … 10 V, analogue frequency monitor, analogue current monitor
Serial port RS485 (Modbus RTU)
Standards CE, UL, cUL, c-Tick
Protection Overcurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop
Environ-mental conditions Temperature / humidity -10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing)
Vibration / lnstallation 5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust
Options Remote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software
Protection class IP20
Weight kg (approx.) 0.8 1.0 1.5 2.4 2.5 1.5 2.3
  80 x 155 x 93 80 x 155 x 107 110 x 189 x 128 110 x 189 x 155
X200 3-phase 400 V class
Model number 004 HFEF 007 HFEF 015 HFEF 022 HFEF 030 HFEF 040 HFEF 055 HFEF 075 HFEF
Applicable motor (kW) 0.4 0.7 1.5 2.2 3.0 4.0 5.5 7.5
Rated output current (A) 1.5 2.5 3.8 5.5 7.8 8.6 13 16
Rated input voltage 3 ~ 380 … 480 V, +10 %, -15 %, 50/60 Hz ±5 %
Rated output voltage 3 ~ 380 … 480 V (corresponding to input voltage)
Integrated EMC filter EN61800-3 category C2 filter
Output frequency range 0.5 … 400 Hz
Frequency accuracy (at 25 °C ±10 °C) Analogue setting: ±0.4 %, digital setting: ±0.01 %
Frequency setting resolution Analogue setting: Maximum frequency/1000, digital setting: 0.1 Hz
V/f characteristics V/f control, V/f variable (constant torque, reduced torque)
Overload capacity 150 % for 60 s
Acceleration/deceleration time 0.01 - 3000 s (linear, sigmoid), two stage accel./decel.
Starting torque 100 % at 6 Hz
Input Intelligent input terminal 10 kOhm input impedance, sink / source logic selectable
Functions FW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR(Safety stop), NO(Not selected)
Output Intelligent output terminal 27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)
Functions RUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load)
Analogue output terminal 0 … 10 V, analogue frequency monitor, analogue current monitor
Serial port RS485 (Modbus RTU)
Standards CE, UL, cUL, c-Tick
Protection Overcurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop
Environ-mental conditions Temperature / humidity -10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing)
Vibration / lnstallation 5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust
Options Remote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software
Protection class IP20
Weight kg (approx.) 1.5 2.3 2.4 5.5 5.7
Dimensions W/H/D in mm 110 x 189 x 128 110 x 189 x 155 180 x 250 x 163

* Item specifications are preliminary and are subject to change without notice